Fluorescence Microscopy
Florochrome Data Tables:
Olympus Cube Data
The data tables below contain reference information on fluorescence cubes offered by Olympus America, Inc. to support their microscopes. The codes for the excitation columns in Tables 2 and 4 and the cube code column in Table 3 are listed in Table 1. Table 2 is a listing of examples of cubes provided for U-URA microscopes. The authors wish to caution that we believe this data to be accurate, but it should always be verified by authorized Olympus representatives.
Filter Color Codes
Code |
Filter Type |
U |
Ultraviolet |
V |
Violet |
BV |
Blue-Violet |
B |
Blue |
IB |
Interference Blue Filter |
G |
Green |
IG |
Immuno Gold Staining Method |
BF |
Brightfield, Phase Contrast, and DIC only |
|
|
|
|
|
Table 1
Table 2 lists the excitation and barrier filters by cube along with the dichroic mirror used in each cube. Use this chart as an aid to guide you in selection of some of the Olympus U-URA cubes for applications listed in our fluorescence and fluorochrome data tables.
Olympus Cubes Offered for U-URA
Excitation |
Cube |
Excitation Filter(nm) |
Dichroic Mirror(nm) |
Barrier Filter |
U |
U-MWU |
330-385 |
400 |
420-- |
U |
U-MNU |
360-370 |
400 |
420-- |
U |
U-MNUBP |
360-370 |
400 |
420-460 |
V |
U-MNV |
400-410 |
455 |
455-- |
BV |
U-MWBV |
400-440 |
455 |
475-- |
BV |
U-MNBV |
420-440 |
455 |
475-- |
B |
U-MWB |
450-480 |
500 |
515-- |
IB |
U-MWIB |
460-490 |
505 |
515IF-- |
IB |
U-MNIB |
470-490 |
505 |
515IF-- |
IB |
U-MNIBBP |
470-490 |
505 |
515-550 |
IB |
U-MWIBBP |
460-490 |
505 |
515-550 |
G |
U-MSWG |
480-550 |
570 |
590-- |
G |
U-MWG |
510-550 |
570 |
590-- |
G |
U-MNG |
530-550 |
570 |
590-- |
IG |
U-MNIG |
520-550 |
565 |
580IF-- |
IY |
U-MWIY |
545-580 |
600 |
610IF-- |
|
|
|
|
|
Where a (--) appears, the filter is a long pass filter.
Table 2
Table 3 lists dichroic mirror/filter combinations for the Olympus BH-2 and Vanox-3 fluorescent illuminators. The authors believe this information to be correct but it should be verified by Olympus representatives. Refer to Table 1 for the codes in the first column of this table.
CODE |
Cube |
Dichroic Mirror |
Exciter Filter |
Barrier Filter |
Supplementary Exciter Filter |
Additional Barrier Filter |
U |
-DMU |
DM400 |
UG1 |
L420 |
|
L435 |
|
Y455 |
V |
-DMV |
DM455 |
BP405 |
Y455 |
|
Y495 |
|
Y495 |
|
515 |
BV |
-DMBV |
DM455 |
BP440 |
AFC |
EL420 |
Y495 |
|
+Y475 |
|
515 |
B |
-DMB |
DM500 |
BP490 |
AFC |
EL455 |
B460 |
|
+O515 |
|
530 |
|
570 |
|
590 |
|
G520 |
IB |
-DMIB |
DM505 |
BP495 |
0515IF |
EY475 |
B460 |
|
530 |
|
570 |
|
590 |
G |
-DMG |
DM570 |
BP545 |
590 |
EO515 |
R610 |
|
EO530 |
|
IGS |
-HMIGS |
(Half-Mirror) |
L420 +PO (Polarizer) |
AN + DP |
|
BF |
-BF |
(Optical axis adjuster) |
(Light beam shutter) |
(Image position adjuster) |
----- |
----- |
|
|
|
|
|
Table 3
Table 4 is a cross-reference for Olympus U-URA cubes to Olympus BH-2, Vanox-3, and IMT-2 cubes. It is advisable to consult the manufacturer's wavelength/transmission curve diagrams for exciter filters, dichroic mirrors and barrier filters to determine how they match the fluorochrome being used. The cube names and nanometer numbers refer to the Olympus U-URA cubes; the figures in parentheses refer to filters still current for BH-2, Vanox 3, and IMT-2 fluorescent cubes.
Excitation |
Cube |
Excitation Filter |
Dichroic Mirror |
Barrier Filter |
U |
U-MU |
BP330-385 |
DM400 |
BA420 |
|
(UG-1) |
|
(L420) |
V |
U-MNV |
BP400-410 |
DM455 |
BA455 |
|
(BP405) |
|
(Y455) |
BV |
U-MWBV |
BP400-440 |
DM455 |
Ba475 |
|
(BP440) |
|
(Y475&AFC) |
BV |
U-MNBV |
BP420-440 |
DM455 |
BA475 |
|
(BP440&EL420) |
|
(Y475&AFC) |
B |
U-MWB |
BP450-480 |
DM500 |
BA515 |
|
(BP490&EY455) |
|
(O515&AFC) |
IB |
U-MWIB |
BP460-490 |
DM505 |
BA515IF |
|
(BP495) |
|
(O515IF) |
IB |
U-MNIB |
BP470-490 |
DM505 |
BA515IF |
|
(BP495&EY455) |
|
(O515IF) |
G |
U-MSWG |
BP480-550 |
DM570 |
BA590 |
|
(BP545) |
|
(O590) |
G |
U-MWG |
BP510-550 |
DM570 |
BA590 |
|
(BP545&EO515) |
|
(O590) |
G |
U-MNG |
BP530-550 |
DM570 |
BA590 |
|
(BP545&EO530) |
|
(O590) |
|
|
|
|
|
Table 4
Use this chart as an aid to guide you in selection of some of the Olympus U-URA cubes if you wish to cross-reference to the extensive listing of fluorochromes in our other data sections.
Contributing Authors
Mortimer Abramowitz - Olympus America, Inc., Two Corporate Center Drive., Melville, New York, 11747.
Michael W. Davidson - National High Magnetic Field Laboratory, 1800 East Paul Dirac Dr., The Florida State University, Tallahassee, Florida, 32310.
BACK TO FLUORESCENCE MICROSCOPY
Questions or comments? Send us an email.
© 1998-2022 by
Michael W. Davidson and The Florida State University.
All Rights Reserved. No images, graphics, scripts, or applets may be reproduced or used in any manner without permission from the copyright holders. Use of this website means you agree to all of the Legal Terms and Conditions set forth by the owners.
Last modification: Tuesday, Sep 11, 2018 at 10:47 AM
Access Count Since July 20, 1998: 35194
For more information on microscope manufacturers, use the buttons below to navigate to their websites:
|